The S-NH3-01 is an industrial-grade IP65rated electrochemical detection of solid polymers with a revolutionary innovative technique in electrochemical detection areas with wide applications in farming, industrial areas, and meteorological monitoring.
Key Features:
Specifications:
The basic parameters | ||||||
Product model | S-NH3-01 | |||||
Supply Voltage | 5 ~ 24V DC (recommended 5V power supply). | |||||
Supported Protocol | MODBUS-RTU RS485 | |||||
IP Rating | IP65 (The equipment should be protected from direct sunlight and rain over long periods of time). | |||||
Operating Temperature | -40°C to 50°C (best operating temperature 20 to 35 °C). | |||||
Operating Humidity | 15 to 95% RH (non-condensation) (best operating humidity 50%RH). | |||||
Ambient Pressure | Atmospheric pressure ±10%. | |||||
Cable Length | 2 meters | |||||
Measurement Parameters | ||||||
Measurement | Measurement accuracy | Resolution | ||||
Ammonia | 0~100 ppm | typ. ±5%F.S, max ±10%F.S | 0.1 ppm | |||
Temperature | -40~50 °C | ± 0.5 °C | 0.1 °C | |||
Humidity | 10~95 %RH | ± 5% | 0.1 %RH | |||
Power | ||||||
Operating Current | 6mA(Max,5V DC);3.2mA(typ.12V DC) | |||||
Performance reference | ||||||
Parameter | Min | Typical value | Max | Unit | ||
RS-485 mode | Warm-up Time [1] | — | 5[2] | — | minutes | |
Poll Rate [3] | — | 1 | — | seconds | ||
Response time[4] | — | 30 | — | seconds | ||
[1] The time from when the sensor is powered on to when the data is read. Note the parameter when the sensor is powered on. [2] If started in an environment with clean air it requires less time [3] The measurement data update interval, after the power-up warm-up time, if the power supply continues, the sensor periodically updates the reading at this interval. [4] T90<30s |