Wiring faults are indicated by one or more of the LEDs failing to illuminate, with the pattern of lit LEDs indicating the type of fault detected. This fail-safe system means that any LED not lit indicates a fault. The robust ABS housing has a sculpted shape for easy removal and there is a look up chart on the tester for quick fault diagnosis.
The plug induces less than 5mA of earth leakage, well below RCD trip thresholds.
Detects 28 fault conditions
Key features
- Mains Supply 200 – 250V (30-70Hz)
- Power Consumption <1.2W
- Temperature Range -10°C to 40°C, 60% RH (max)
- Earth Leakage <5mA
- Overvoltage CAT II, 300V
- Housing Flame retardant ABS
- Dimensions 65 x 65 x 47mm